MOXA EtherDevice™ Switch EDS-518A Series User’s Manual www.moxa.com/product First Edition, April 2006 MOXA Networking Co., Ltd. Tel: +
EDS-518A Series User’s Manual Getting Started 2-33. The Communication Parameter page of the Property window opens. Select the appropriate COM port
EDS-518A Series User’s Manual Getting Started 2-46. The Console login screen will appear. Press Enter to open the Account pop-up selector and then
EDS-518A Series User’s Manual Getting Started 2-5Configuration using a Telnet Console You may use Telnet to access EDS-518A’s console utility over a
EDS-518A Series User’s Manual Getting Started 2-63. The Console login screen will appear. Press Enter to open the Account pop-up selector and then
EDS-518A Series User’s Manual Getting Started 2-7NOTE Before accessing EDS-518A’s web browser interface, first connect one of its RJ45 Ethernet port
EDS-518A Series User’s Manual Getting Started 2-8 Disabling Telnet and Browser Access If you are connecting EDS-518A to a public network, but do not
33 Chapter 3 Featured Functions This chapter explains how to access EDS-518A’s various configuration, monitoring, and administration functions. Th
EDS-518A Series User’s Manual Featured Functions 3-2Configuring Basic Settings The Basic Settings group includes the most commonly used settings req
EDS-518A Series User’s Manual Featured Functions 3-3Password EDS-518A provides two levels of access privileges: admin privilege gives read/write acc
EDS-518A Series User’s Manual Featured Functions 3-4Accessible IP MOXA EDS-518A uses an IP address-based filtering method to control access to EDS-5
MOXA EtherDevice™ Switch EDS-518A Series User’s Manual The software described in this manual is furnished under a license agreement and may be used o
EDS-518A Series User’s Manual Featured Functions 3-5Port Port settings are included to give the user control over Port Access, Port Transmission Spe
EDS-518A Series User’s Manual Featured Functions 3-6Speed Setting Description Factory Default Auto Allows the port to use the IEEE 802.3u protoco
EDS-518A Series User’s Manual Featured Functions 3-7Auto IP Configuration Setting Description Factory DefaultDisable Set up EDS-518A’s IP address
EDS-518A Series User’s Manual Featured Functions 3-8Time EDS-518A has a time calibration function based on information from an NTP server or user s
EDS-518A Series User’s Manual Featured Functions 3-9Time Server IP/Name Setting Description Factory Default1st Time Server IP/Name IP or Domain a
EDS-518A Series User’s Manual Featured Functions 3-10Log Files Path and Name Setting Description Factory DefaultMax. 40 Characters The path and f
EDS-518A Series User’s Manual Featured Functions 3-11Factory Default The Factory Default function is included to give users a quick way of restorin
EDS-518A Series User’s Manual Featured Functions 3-12If all ports on both switch units are configured as 100BaseTX and they are operating in full du
EDS-518A Series User’s Manual Featured Functions 3-13Trunk Group (Maximum of 3 trunk groups) Setting Description Factory DefaultTrk1, Trk2, Trk3
EDS-518A Series User’s Manual Featured Functions 3-14Configuring SNMP EDS-518A supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community string
Table of Contents Chapter 1 Introduction ...1-1 Overvie
EDS-518A Series User’s Manual Featured Functions 3-15V1, V2c Write/Read Community Setting Description Factory Default V1, V2c Read/Write Community
EDS-518A Series User’s Manual Featured Functions 3-16User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only) Setting Description Factory Defau
EDS-518A Series User’s Manual Featured Functions 3-17Turbo Ring and STP/RSTP cannot both be used on the network at the same time. The following tabl
EDS-518A Series User’s Manual Featured Functions 3-18Initial Setup 1. Select any two ports as redundant ports. 2. Connect the redundant ports to
EDS-518A Series User’s Manual Featured Functions 3-19When the number of EDS-518A units in the Turbo Ring is odd. MasterSegment N+1 If there are 2N+1
EDS-518A Series User’s Manual Featured Functions 3-20Decide appropriate coupling ports in each switch and link them together. Next, assign one switc
EDS-518A Series User’s Manual Featured Functions 3-21Redundant Port Status This field indicates the current status of redundant ports. The state is
EDS-518A Series User’s Manual Featured Functions 3-22Rapid Spanning Tree Protocol (RSTP) implements the Spanning Tree Algorithm and Protocol defined
EDS-518A Series User’s Manual Featured Functions 3-23 What happens if a link failure is detected? As shown in next figure, the STP process reconfigu
EDS-518A Series User’s Manual Featured Functions 3-24y Each port has a cost that specifies the efficiency of each link. The efficiency cost is usua
The Concept of Multicast Filtering ... 3-40 Configuring IGMP Snooping ...
EDS-518A Series User’s Manual Featured Functions 3-25STP Example The LAN shown in the following figure has three segments, with adjacent segments co
EDS-518A Series User’s Manual Featured Functions 3-26The following figure shows an example of a network that contains VLANs 1 and 2. The VLANs are c
EDS-518A Series User’s Manual Featured Functions 3-27Now Active: This will show which communication protocol is being used—Turbo Ring, RSTP, or neit
EDS-518A Series User’s Manual Featured Functions 3-28Enable STP per Port Setting Description Factory DefaultEnable/Disable Select to enable the p
EDS-518A Series User’s Manual Featured Functions 3-29Using Traffic Prioritization EDS-518A’s traffic prioritization capability provides Quality of S
EDS-518A Series User’s Manual Featured Functions 3-30IEEE 802.1p Priority Level IEEE 802.1D Traffic Type 0 Best Effort (default) 1 Background 2 Sta
EDS-518A Series User’s Manual Featured Functions 3-312. As the 802.1p priority levels are fixed to the traffic queues, the packet will be placed in
EDS-518A Series User’s Manual Featured Functions 3-32Queuing Mechanism Setting Description Factory DefaultWeighted Fair EDS-518A has 4 priority q
EDS-518A Series User’s Manual Featured Functions 3-33CoS Mapping Setting Description Factory Low/Normal/ Medium/High Set the mapping table of dif
EDS-518A Series User’s Manual Featured Functions 3-34Using Virtual LAN Setting up Virtual LANs (VLANs) on your EDS-518A increases the efficiency of
11 Chapter 1 Introduction Welcome to MOXA EtherDevice Switch EDS-518A Series, the Gigabit Managed Redundant Ethernet Switch designed specially for
EDS-518A Series User’s Manual Featured Functions 3-35y VLANs provide extra security: Devices within each VLAN can only communicate with other devic
EDS-518A Series User’s Manual Featured Functions 3-36y Access Port: The port connects to a single device that is not tagged. The user must define t
EDS-518A Series User’s Manual Featured Functions 3-37y Port 6 connect a single untagged device and assigns it to VLAN 5; it should be configured as
EDS-518A Series User’s Manual Featured Functions 3-38Management VLAN ID Setting Description Factory DefaultVLAN ID ranges from 1 to 4094 Set the m
EDS-518A Series User’s Manual Featured Functions 3-39 VLAN Mode Setting Description Factory Default802.1Q VLAN Set VLAN mode to 802.1Q VLAN Port-
EDS-518A Series User’s Manual Featured Functions 3-40NOTE The physical network can have a maximum of 64 VLAN settings. Using Multicast Filtering Mul
EDS-518A Series User’s Manual Featured Functions 3-41Network without multicast filtering 12345678Serial portsConsole LAN9 10111213141516IGMP Group2G
EDS-518A Series User’s Manual Featured Functions 3-42Query Mode Query mode allows the EDS-518A to work as the Querier if it has the lowest IP addres
EDS-518A Series User’s Manual Featured Functions 3-43Enabling Multicast Filtering Use the serial console or Web interface to enable or disable IGMP
EDS-518A Series User’s Manual Featured Functions 3-44Static Multicast Router Port Setting Description Factory DefaultSelect/Deselect Select the o
EDS-518A Series User’s Manual Introduction 1-2Overview As the world’s network and information technology becomes more mature, the trend is to use Et
EDS-518A Series User’s Manual Featured Functions 3-45Join Port Setting Description Factory DefaultSelect/Deselect Select the appropriate options
EDS-518A Series User’s Manual Featured Functions 3-46Using Bandwidth Management In general, one host should not be allowed to occupy unlimited bandw
EDS-518A Series User’s Manual Featured Functions 3-47Ingress Setting Description Factory DefaultIngress rate Select the ingress rate for all pack
EDS-518A Series User’s Manual Featured Functions 3-48Message ExchangeAuthenticationserver(RADIUS)ClientEAPOL-StartEAP-Request/IdentityEAP-Response/I
EDS-518A Series User’s Manual Featured Functions 3-497. The authenticator sends “EAP Success” or “EAP Failure” based on the reply from the authenti
EDS-518A Series User’s Manual Featured Functions 3-50Radius Server Setting Description Factory DefaultIP address or domain name The IP address or
EDS-518A Series User’s Manual Featured Functions 3-51802.1X Re-Authentication EDS-518A can force connected devices to be re-authorized manually. 80
EDS-518A Series User’s Manual Featured Functions 3-52Local User Database Setup Setting Description Factory DefaultUser Name (Max. 30 characters) U
EDS-518A Series User’s Manual Featured Functions 3-53Configuring Email Warning The Auto Email Warning function uses e-mail to alert the user when ce
EDS-518A Series User’s Manual Featured Functions 3-54System Events Warning e-mail is sent when… Switch Cold Start Power is cut off and then reconn
EDS-518A Series User’s Manual Introduction 1-3Useful Utility and Remote Configuration y Configurable using a Web browser, Telnet/Serial console, an
EDS-518A Series User’s Manual Featured Functions 3-55Email Setup Mail Server IP/Name Setting Description Factory DefaultIP address The IP Addres
EDS-518A Series User’s Manual Featured Functions 3-56NOTE Auto warning e-mail messages will be sent through an authentication protected SMTP server
EDS-518A Series User’s Manual Featured Functions 3-57System Events Warning Relay output is triggered when… Power Transition (OnÆOff) EDS-518A is p
EDS-518A Series User’s Manual Featured Functions 3-58Configuring Line-Swap Fast Recovery Enable Line-Swap-Fast-Recovery Setting Description Facto
EDS-518A Series User’s Manual Featured Functions 3-59• When using the Console utility, activate by first highlighting the Activate menu option, and
EDS-518A Series User’s Manual Featured Functions 3-60STEP 1 Configure EDS-518A’s Mirror Port function from either the Console utility or Web Browser
EDS-518A Series User’s Manual Featured Functions 3-61graph displays data transmission activity by showing Packets/s (i.e., packets per second, or pp
EDS-518A Series User’s Manual Featured Functions 3-62Using the MAC Address Table This section explains the information provided by EDS-518A’s MAC ad
EDS-518A Series User’s Manual Featured Functions 3-63Bootup This field shows how many times the EDS-518A has been rebooted or cold started.Date Th
EDS-518A Series User’s Manual Featured Functions 3-643. Select Yes to enter the EDS-518A’s web browser interface and access the web browser interfa
22 Chapter 2 Getting Started This chapter explains how to access EDS-518A for the first time. There are three ways to access the switch: serial co
44 Chapter 4 EDS Configurator GUI EDS Configurator is a comprehensive Windows-based GUI that is used to configure and maintain multiple EDS-518A s
EDS-518A Series User’s Manual EDS Configurator GUI 4-2Starting EDS Configurator To start EDS Configurator, locate and then run the executable file e
EDS-518A Series User’s Manual EDS Configurator GUI 4-3Once the search is complete, the Configurator window will display a list of all switches that
EDS-518A Series User’s Manual EDS Configurator GUI 4-4 3. Click the Upgrade Firmware toolbar icon, or select Upgrade under the Firmware menu. If th
EDS-518A Series User’s Manual EDS Configurator GUI 4-5Export Configuration The Export Configuration utility is used to save the entire configuration
EDS-518A Series User’s Manual EDS Configurator GUI 4-6Import Configuration The Import Configuration function is used to import an entire configurati
EDS-518A Series User’s Manual EDS Configurator GUI 4-74. Click Yes in response to the following warning message to accept the new settings. Unlock
EDS-518A Series User’s Manual EDS Configurator GUI 4-82. When the Unlock status window reports Progress as OK, click the Close button in the upper
AA Appendix A MIB Groups MOXA EDS-518A comes with built-in SNMP (Simple Network Management Protocol) agent software that supports cold/warm start
EDS-518A Series User’s Manual MIB Groups A-2MIB II.10 – Transmission Group dot3 dot3StatsTable MIB II.11 – SNMP Group SnmpBasicGroup
EDS-518A Series User’s Manual Getting Started 2-2RS-232 Console Configuration (115200, None, 8, 1, VT100) NOTE Connection Caution! 1. You cannot co
EDS-518A Series User’s Manual MIB Groups A-3EDS-518A also provides a private MIB file, located in the file “MOXA-EDS518A-MIB.my” on the EDS-518A Ser
BB Appendix B Specifications Technology Standards IEEE802.3, 802.3u, 802.3x, 802.1D, 802.1w, 802.1Q, 802.1p Protocols IGMP V1/V2/V3 device, GVR
EDS-518A Series User’s Manual Specifications B-2Min. TX Output: Multi mode : -20 dBm Single mode: 0 to 40 km, -5 dBm 0 to 80 km, -5 dBm Max. T
EDS-518A Series User’s Manual Specifications B-3Environmental Operating Temperature 0 to 60°C (32 to 140°F) Storage Temperature -40 to 85°C (-40
CC Appendix C Service Information This appendix shows you how to contact MOXA for information about this and other products, and how to report pro
EDS-518A Series User’s Manual Service Information C-2MOXA Internet Services Customer satisfaction is our primary concern. To ensure that customers r
EDS-518A Series User’s Manual Service Information C-3Problem Report Form MOXA EDS-518A Series Customer name: Company: Tel: Fax: Email: Date: Seri
EDS-518A Series User’s Manual Service Information C-4Product Return Procedure For product repair, exchange, or refund, the customer must: Provid
Kommentare zu diesen Handbüchern