Moxa-technologies 5400 Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Moxa-technologies 5400 herunter. Moxa Technologies 5400 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - User’s Manual

5400 Series User’s Manual Third Edition, May 2004

Seite 2

Panel Layout NPort 5410 NPort 5430/5430I NPort 5400 Series User’s Manual 2-2

Seite 3 - Table of Contents

Getting Started Connecting the Hardware This section describes how to connect NPort 5400 to serial devices for first time testing purposes. We cover W

Seite 4

Grounding NPort 5400 Grounding and wire routing helps limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection

Seite 5 - Introduction

33 Chapter 3 Initial IP Address Configuration When setting up your NPort 5410/5430/5340I for the first time, the first thing you should do is confi

Seite 6 - Product Features

Initializing NPort’s IP Address 1. Determine whether your NPort needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application). 2. If NP

Seite 7 - Product Specifications

Initial IP Address Configuration There are four push buttons on NPort’s nameplate. Going from left to right, the buttons are: Button Name Action MENU

Seite 8

As you use the buttons to operate the LCM display, you will notice that with very few exceptions, moving up one level causes the bottom line of the d

Seite 9 - Getting Started

Initial IP Address Configuration The part of the LCM operation that still requires some explanation is how to edit the configurable options. In fact,

Seite 10 - Panel Layout

NPort Administration Suite NPort Administration Suite consists of some useful utility programs that are used to configure and manage your NPorts. See

Seite 11 - Connecting the Hardware

Initial IP Address Configuration Telnet Console Depending on how your computer and network are configured, you may find it convenient to use network a

Seite 12 - LED Indicators

5400 Series User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the t

Seite 13

6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter. 7. Press any key to continue… 8. Type

Seite 14 - LCM Display

Initial IP Address Configuration 9. Type s and then press Enter to Save/Restart the system. 10. Type y and then press Enter to save the new IP addres

Seite 16

44 Chapter 4 Choosing the Proper Operation Mode In this section, we describe the various NPort operation modes. The options include an operation m

Seite 17

Overview NPort Device Servers network-enable traditional RS-232/422/485 devices, in which a Device Server is a tiny computer equipped with a CPU, rea

Seite 18 - NPort Administration Suite

Choosing the Proper Operation Mode TCP Client Mode In TCP Client mode, NPort can actively establish a TCP connection to a pre-defined host computer wh

Seite 19 - Telnet Console

The driver used for Real COM Mode comes with the NPort Windows Administrator which will install automatically on your computer when you install NPor

Seite 20

55 Chapter 5 Web Console Configuration The Web Console is the most user-friendly way to configure NPort 5410/5430/5340I. This chapter will introdu

Seite 21

Opening Your Browser 1. Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Interne

Seite 22

Web Console Configuration 4. The NPort 5410/5430/5340I homepage will open. On this page, you can see a brief description of the Web Console’s nine fu

Seite 23 - Real COM Mode

Table of Contents Chapter 1 Introduction...1-1 Overview ...

Seite 24

Basic Settings Server name Setting Factory Default Necessity 1 to 39 characters NP[model name]_[Serial No.] Optional This option is useful for s

Seite 25

Web Console Configuration Click on the Modify button to open the Modify time settings window to input the correct local time. Time server Setting Fac

Seite 26

NPort 5400 Series User’s Manual 5-6

Seite 27 - Web Console Configuration

Web Console Configuration You must assign a valid IP address to NPort 5410/5430/5340I before it will work in your network environment. Your network sy

Seite 28 - Opening Your Browser

IP Configuration Setting Factory Default Necessity Static DHCP DHCP/BOOTP BOOTP Static Required In Dynamic IP environments, the firmware will ret

Seite 29

Web Console Configuration SNMP Settings Community Name Setting Factory Default Necessity 1 to 39 characters (E.g., Support, 886-89191230 #300) publi

Seite 30 - Basic Settings

Serial Settings Click on Serial Settings, located under Main Menu, to display serial port settings for ports 1 and 2. To modify serial settings for

Seite 31 - Network Settings

Web Console Configuration Serial Parameters Check the serial communication parameters in your Serial Device’s user’s manual. You should set up NPort

Seite 32

Operating Settings Press Operating Settings to display the operating settings for all of NPort’s serial ports. Real COM Mode TCP alive check time

Seite 33

Web Console Configuration Max Connection Setting Factory Default Necessity 1, 2, 3, 4 1 Required Max Connection is usually used when the user nee

Seite 34

Chapter 6 Configuring Windows Administrator ...6-1 Overview ...

Seite 35 - IP Address Report

Force Transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0: Disable the force transmit timeout. 1 to 65535: Forces the NPort’

Seite 36 - Serial Settings

Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed du

Seite 37 - Serial Parameters

Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the NPort receives both delimiters through its serial port, it immediat

Seite 38 - Operating Settings

Web Console Configuration TCP Client Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection

Seite 39

At least, the Inactivity time should be set larger than that of Force Transmit timeout. To prevent the unintended loss of data due to the session di

Seite 40

Web Console Configuration Destination IP address 1 Setting Factory Default Necessity IP address or Domain Address (E.g., 192.168.1.1) None Required Al

Seite 41

UDP Mode Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None

Seite 42

Web Console Configuration Force Transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0: Disable the force transmit timeout. 1 to

Seite 43

Accessible IP Settings NPort has an IP address based filtering method to control access to the NPort. Accessible IP Settings allows you to add or r

Seite 44

Web Console Configuration Auto Warning Settings Event Type Cold start This refers to starting the system from power off (contrast this with warm star

Seite 45

11 Chapter 1 Introduction Welcome to MOXA NPort 5400 Series of advanced serial device servers that make it easy to network enable your serial devic

Seite 46

DSR changed The DSR (Data Set Ready) signal has changed, also indicating that the data communication equipment’s power is off. For example, a DSR ch

Seite 47

Web Console Configuration Auto warning: E-mail and SNMP Trap Mail Server Mail Server Setting Factory Default Necessity IP or Domain Name None Opt

Seite 48 - Accessible IP Settings

Change Password Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase the password. In this cas

Seite 49 - Auto Warning Settings

Web Console Configuration Load Factory Default This function will reset all of NPort’s settings to the factory default values. Be aware that previous

Seite 51 - SNMP Trap Server

66 Chapter 6 Configuring Windows Administrator This chapter uses NPort 5230 as an example to introduce the installation and configuration of NPort

Seite 52 - Change Password

Overview We understand the importance of software as the foundation of your application, and with this in mind, we designed NPort Administrator to le

Seite 53 - Load Factory Default

Configuring Windows Administrator 4. Click on Next to install the program using the default program name, or select a different name. 5. Click on Ins

Seite 54

8. Click on Finish to complete the installation of NPort Administration Suite. Configuration The Administrator-Configuration window is divided into

Seite 55

Configuring Windows Administrator Broadcast Search The Broadcast Search function is used to locate all NPorts that are connected to the same LAN as yo

Seite 56

Overview NPort 5400 Series serial device servers are designed to make your industrial serial devices Internet ready instantly. The compact size of NP

Seite 57

Unlock Password Protection If the NPort is password protected, then you will not be able to use the right click or double click method to open the c

Seite 58 - Configuration

Configuring Windows Administrator Blank The NPort is not password protected, and “Broadcast Search” was used to locate it. Fixed The NPort is not pass

Seite 59 - Broadcast Search

Upgrade Firmware Input the password to Unlock the NPort, and then right click on a specific NPort and select the Upgrade Firmware function to start u

Seite 60 - Unlock Password Protection

Configuring Windows Administrator Export/Import Right click on a specific NPort and select the Export function to start Exporting the configuration f

Seite 61

Monitor There are two methods available to start the Monitor function. 1. First use Broadcast Search under the Configuration Function group, and then

Seite 62 - Upgrade Firmware

Configuring Windows Administrator Select Monitor Items. Select a Refresh Rate (the default is 3 seconds). Select Display warning message or Play the

Seite 63 - Export/Import

When one of the NPorts loses connection with the Monitor program, a warning alert will display automatically. The warning music will be played at the

Seite 64 - Monitor

Configuring Windows Administrator Port Monitor The process is the same as in the previous “Monitor” section. The only difference is that you can selec

Seite 65

COM Mapping Windows Administration Suite comes with the Windows 95/98/ME/NT/2000/XP Real COM drivers. After you install Windows Administration Suite,

Seite 66

Configuring Windows Administrator Select COM Setting to modify COM No., default setting, etc. Select the COM No. Those “In use,” “Assigned” COM ports

Seite 67 - Port Monitor

Introduction Product Specifications LAN Ethernet 10/100 Mbps, RJ45 Protection Built-in 1.5 KV magnetic isolation NPort 5410 Serial Interface Interf

Seite 68 - COM Mapping

Fast Flush (only flush local buffer) 1. We have added one optional “Fast Flush” function in our new NPort Real COM driver. NPort Administrator Suite

Seite 69

Configuring Windows Administrator Select Discard Change to tell Administrator to NOT save the COM Mapping information to the host. To save the config

Seite 70

Add a target by inputting the IP address and selecting the Model Name without physically connecting the NPort to the network. Apply change. IP Lo

Seite 71 - Off-line COM Mapping

Configuring Windows Administrator Select the IP Location Report. The configure the local listen to be the same as the NPort’s “Auto report to UDP po

Seite 73

77 Chapter 7 IP Serial LIB The following topics are covered in this chapter:  Overview  IP Serial LIB Function Groups  Example Program

Seite 74

Overview What is IP Serial Library? IP Serial Library is a Windows library with frequently used serial command sets and subroutines. IP Serial Librar

Seite 75 - IP Serial LIB

IP Serial LIB IP Serial LIB Function Groups Server Control Port Control Input/Output Data Port Status Inquiry Miscellaneous nsio_init nsio_end nsio_

Seite 77 - Example Program

AA Appendix A Pinouts and Cable Wiring In this appendix, we cover the following topics.  Port Pinout Diagrams  Ethernet Port Pinouts  Serial

Seite 78

Power Requirements Power Input 12 to 48 VDC Power Consumption NPort 5410: 385 mA (at 12V max.) NPort 5430: 380 mA (at 12V max.) NPort 5430I:

Seite 79 - Pinouts and Cable Wiring

Port Pinout Diagrams Ethernet Port Pinouts Serial Port Pinouts DB9 Male RS-232 Port Pinouts for NPort 5410 Terminal Block RS-232 & RS-422/485

Seite 80 - Port Pinout Diagrams

Pinouts and Cable Wiring Cable Wiring Diagrams Ethernet Cables Serial Cables DB9 Female to DB9 Male for NPort 5410 NPort 5400 Series User’s

Seite 81 - Cable Wiring Diagrams

DB9 Female to DB25 Male for NPort 5410 NPort 5400 Series User’s Manual A-4

Seite 82

BB Appendix B Well Known Port Numbers This appendix is for your reference about the Well Known port numbers that may cause network problem if you

Seite 83 - Well Known Port Numbers

49 (Login Host Protocol) (Login) 53 Domain Name Server (domain) 79 Finger protocol (Finger) TCP Socket Application Service 80 World Wibe Web HTTP

Seite 84

CC Appendix C SNMP Agent with MIB II & RS-232 like group NPort 5200 has a built-in SNMP (Simple Network Management Protocol) agent software. I

Seite 85

System MIB Interfaces MIB IP MIB ICMP MIB SysServices ifInUnknownProtos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs i

Seite 86

Well Known Port Numbers Address Translation MIB TCP MIB SNMP MIB AtNetAddress tcpRetransSegs snmpInTotalSetVars tcpConnState snmpInGetRequests t

Seite 88

DD Appendix D Service Information This appendix shows you how to contact Moxa for information about this and other products, and how to report prob

Seite 89 - Service Information

22 Chapter 2 Getting Started This chapter includes information about installing NPort 5400 Series. The following topics are covered:  Panel Layou

Seite 90 - MOXA Internet Services

MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa I

Seite 91 - MOXA NPort 5400 Series

Service Information Problem Report Form MOXA NPort 5400 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product:  NPort 5410

Seite 92 - Product Return Procedure

Product Return Procedure For product repair, exchange, or refund, the customer must:  Provide evidence of original purchase.  Obtain a Product Ret

Seite 93 - Revision History

Service Information Revision History Document Edition Revision Date Revision Details 2nd August 25, 2003 1. Update the edition of this manual on

Seite 94

the title page. 3. p. 6-16 Added descriptions on newly-added function “Fast Flush”. 4. p. 4-3 Added more descriptions on Real COM Mode. 5. p. 5-13

Seite 95 - Auto IP Report Protocol

EE Appendix E Auto IP Report Protocol NPort Series provides several ways to configure Ethernet IP addresses. One of them is DHCP Client. When you s

Seite 96

NPort 5400 Series User’s Manual E-2And then you can develop your own programs to receive this information from the NPort. Here is NPort’s Auto IP Rep

Kommentare zu diesen Handbüchern

Keine Kommentare