EDS-408A/405A Series User’s Manual Featured Functions
3-55
Using Event Log
Bootup
This field shows how many times the EDS has been rebooted or cold
started.
Date
The date is updated based on how the current date is set in the “Basic
Setting” page.
Time
The time is updated based on how the current time is set in the “Basic
Setting” page.
System Startup Time The system startup time related to this event.
Events Events that have occurred.
Events are logged in the EDS-408A/405A Event Log when the following events occur:
1. Cold start
2. Warm start
3. Configuration Change Activated
4. Power Transition from OFF to ON or from ON to OFF
5. Authentication Fail
6. Topology Changed
7. Master Setting is Mismatched
8. Port Traffic Overload
9. Port Link from OFF to ON or from ON to OFF
Using Syslog
This function provides the event logs for the syslog server. The function supports 3 configurable
syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent
as a syslog UDP packet to the specified syslog servers.