Moxa Technologies INTELLIO C218 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach PC / Workstation Barebones Moxa Technologies INTELLIO C218 herunter. Moxa Technologies INTELLIO C218 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 91
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Intellio C218Turbo/PCI User’s Manual
A High Performance 8 Port Async Board for PCI Bus
Dec. 1999 (4th Edition)
The content of this manual is also available in CD-ROM and at Moxa Web Site.
Moxa Technologies Co., Ltd.
Tel: +866-2-8665-6373
Fax: +886-2-8665-6372
www.moxa.com
Seitenansicht 0
1 2 3 4 5 6 ... 90 91

Inhaltsverzeichnis

Seite 1 - Dec. 1999 (4th Edition)

Intellio C218Turbo/PCI User’s ManualA High Performance 8 Port Async Board for PCI BusDec. 1999 (4th Edition)The content of this manual is also availab

Seite 2 - Disclaimer

1-4 Intellio C218Turbo /PCI User's ManualCheck ListUpon unpacking Intellio C218Turbo/PCI 8-port high performance intelligent asyncboard, you sho

Seite 3 - MOXA Internet Services

IntroductionIntellio C218Turbo /PCI User's Manual 1-5Installation GuideThis section gives a brief summary of how to install the Intellio C218Tur

Seite 4 - About This Manual

1-6 Intellio C218Turbo /PCI User's Manual

Seite 5 - Table of Contents

Intellio C218Turbo /PCI User's Manual 2-122 2 Hardware InstallationHardware InstallationHardware InstallationHardware InstallationThe installat

Seite 6

2-2 Intellio C218Turbo /PCI User's ManualStep 7: Connect one of the connection box/cable (also adapter if required) detailedin the next Section.

Seite 7 - Introduction

Hardware InstallationIntellio C218Turbo /PCI User's Manual 2-3Opt8C/Opt8DHold one end of the DB62 cable and plug it into the DB62 connector on t

Seite 8 -  Industrial Automation

2-4 Intellio C218Turbo /PCI User's ManualOperating Opt8JOpt8J is the RS-422/485 connection box with 8 port female DB25 connectors forMOXA 8 port

Seite 9 - Features

Intellio C218Turbo /PCI User's Manual 3-133 3 Software InstallationSoftware InstallationSoftware InstallationSoftware InstallationIn this chapt

Seite 10 - Check List

3-2 Intellio C218Turbo /PCI User's ManualInstalling DriverThe following is the procedure for installing the Intellio C218Turbo/PCI driver forthe

Seite 11 - Installation Guide

Software InstallationIntellio C218Turbo /PCI User's Manual 3-35. Select “MOXA Intellio Family Multiport Board” in the “Select OEM Option”dialog

Seite 12

Intellio C218Turbo/PCI User’s ManualThe software described in this manual is furnished under a license agreement and may be used only inaccordance wit

Seite 13 - Hardware Installation

3-4 Intellio C218Turbo /PCI User's ManualYou have to set up all the ports of the board with the desired “COM number”,which should not conflict w

Seite 14 - Opt8A/Opt8B/Opt8S

Software InstallationIntellio C218Turbo /PCI User's Manual 3-5In the “Advanced Settings” dialog, you may customize the driver with thefollowing

Seite 15 - C218 Turbo/PCI

3-6 Intellio C218Turbo /PCI User's Manual8. Click [OK] in the “Individual Port Setting” and the “Property” dialog boxes togo back to the “MOXA C

Seite 16 - Operating Opt8J

Software InstallationIntellio C218Turbo /PCI User's Manual 3-7 Enter [Administrative] group, then open [Event Viewer] icon and then select[App

Seite 17 - Software Installation

3-8 Intellio C218Turbo /PCI User's Manual3. Click on [Properties…] button to start the “MOXA Configuration Panel”dialog.In this configuration p

Seite 18 - Installing Driver

Software InstallationIntellio C218Turbo /PCI User's Manual 3-9Adding/Removing BoardFollowing is the procedure to add/remove Intellio C218Turbo/P

Seite 19

3-10 Intellio C218Turbo /PCI User's ManualWindows 95/98Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fullyintegrate the

Seite 20

Software InstallationIntellio C218Turbo /PCI User's Manual 3-11The following flow chart illustrates the driver installation stages of the Intel

Seite 21

3-12 Intellio C218Turbo /PCI User's ManualFirst Time Driver Installation StageThe stage presents the steps for installing the driver for the fir

Seite 22

Software InstallationIntellio C218Turbo /PCI User's Manual 3-133. Type “A:\Windows.95” in the Location field,and click [OK]. The system will sta

Seite 23 - Configuring Board and Port

MOXA Internet ServicesCustomer’s satisfaction is always our number one concern. To ensure that customers get the full benefit ofour services, Moxa Int

Seite 24

3-14 Intellio C218Turbo /PCI User's Manual6. Click [Next>].7. Click [Next>].

Seite 25 - Removing Driver

Software InstallationIntellio C218Turbo /PCI User's Manual 3-15Port Configuration StageThis stage displays the “MOXA Ports Installation” dialog

Seite 26 - Windows 95/98

3-16 Intellio C218Turbo /PCI User's Manual In the “Advanced Settings” dialog box, you may customize the driver with thefollowi

Seite 27

Software InstallationIntellio C218Turbo /PCI User's Manual 3-17Board and Port Ready StageClick on [OK] buttons for all the dialog boxes to finis

Seite 28

3-18 Intellio C218Turbo /PCI User's ManualOnce the installation is finished, error conditions of the board, if any, are displayedon the screen.

Seite 29

Software InstallationIntellio C218Turbo /PCI User's Manual 3-19Configuring Board and PortIf you already have installed the driver and want to re

Seite 30 - 7. Click [Next>]

3-20 Intellio C218Turbo /PCI User's Manual3. In the “Property” dialog, you may click on [Port Setting] button to enter thefollowing “Individual

Seite 31 - Port Configuration Stage

Software InstallationIntellio C218Turbo /PCI User's Manual 3-21In the “Individual Port Setting” dialog box, you may have two ways to map thephys

Seite 32

3-22 Intellio C218Turbo /PCI User's ManualIn the “Advanced Settings” dialog box, you may customize the driver with thefollowing two features:

Seite 33 - Board and Port Ready Stage

Software InstallationIntellio C218Turbo /PCI User's Manual 3-23Updating driverOpen the [Control Panel] and click on the [System] button, and sel

Seite 34

About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog

Seite 35

3-24 Intellio C218Turbo /PCI User's ManualUNIXThere are various UNIX operating systems, such as SCO UNIX, UNIX SVR4.2,XENIX and Solaris, etc. Di

Seite 36

Software InstallationIntellio C218Turbo /PCI User's Manual 3-25MOXA UNIX Device Driver Installation Ver. x.xPlease select one of the following O

Seite 37

3-26 Intellio C218Turbo /PCI User's ManualFor more details, see later section “Administration Utility -mxadm”. Up to now, you have already compl

Seite 38 -  Transmission Mode

Software InstallationIntellio C218Turbo /PCI User's Manual 3-27MOXA TTY Device Naming ConventionIf the Intellio C218Turbo/PCI is successfully co

Seite 39 - Removing driver

3-28 Intellio C218Turbo /PCI User's ManualAdministration Utility - mxadmYou can use the administration utility, mxadm, to change the IntellioC21

Seite 40

Software InstallationIntellio C218Turbo /PCI User's Manual 3-29In the “Basic Configuration” dialog, you should first press Enter in board type f

Seite 41

3-30 Intellio C218Turbo /PCI User's ManualAdvanced ConfigurationThis is to provide advanced settings for advanced driver features beyond basicse

Seite 42

Software InstallationIntellio C218Turbo /PCI User's Manual 3-312. Press PageDown to enter “Advanced Port Settings” sub-dialog, there are somenot

Seite 43

3-32 Intellio C218Turbo /PCI User's ManualResponseThree levels, Slow, Normal and Fast, of port response time are designed foruser's need. P

Seite 44 - Basic Configuration

Software InstallationIntellio C218Turbo /PCI User's Manual 3-33Performance TuningThe utility let you tune the favored response time for those po

Seite 45 - Non-Modem and Modem Baud Rate

Table of ContentsIntroduction ... 1-1Overview ...

Seite 46 - Baud Rate Mapping

3-34 Intellio C218Turbo /PCI User's ManualHowever, before the board reset is issued, you must make sure that1. All enabled ports must be disable

Seite 47

Software InstallationIntellio C218Turbo /PCI User's Manual 3-35Setting MOXA Ports to TerminalFollowing procedure is how to set the MOXA port to

Seite 48 - RTS/CTS Hardware Flow Control

3-36 Intellio C218Turbo /PCI User's Manual

Seite 49 - Board Reset

Intellio C218Turbo /PCI User's Manual 4-144 4 Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsM

Seite 50 - Driver Removal

4-2 Intellio C218Turbo /PCI User's ManualPComm Programming LibraryThe serial communication library is to assist users to develop programs for se

Seite 51

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-3Diagnos

Seite 52

4-4 Intellio C218Turbo /PCI User's ManualMonitor (for MOXA boards under Windows NT Only)A useful port status monitoring program allows you to wa

Seite 53 - Serial Programming Tools

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-5Termina

Seite 54 - Utilities

4-6 Intellio C218Turbo /PCI User's ManualUNIXProgramming the MOXA PortsThe system calls that apply to standard tty port can also be applied to M

Seite 55

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-7Syntax

Seite 56

UNIX... 4-6Programming the MOXA Ports..

Seite 57 - Terminal Emulator

4-8 Intellio C218Turbo /PCI User's Manualioc.ic_cmd = MOBUFED;ioc.ic_timout = 0;ioc.ic_len = sizeof(int);ioc.ic_dp = (char *)&count;ioctl(mo

Seite 58 - Programming the MOXA Ports

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-9Syntax

Seite 59 - 2. MOBUFED

4-10 Intellio C218Turbo /PCI User's ManualSyntax for SCO UNIX/XENIX#define MLOWATER 0x405int lowater; /* low water value of output buffer (defa

Seite 60 - 4. MTCDTR

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-117. MHW

Seite 61 - 5. MLOWATER

4-12 Intellio C218Turbo /PCI User's ManualUtilitiesYou can use the administration utility, mxadm, to monitor port activity and to doterminal emu

Seite 62 - 6. MSTATUS

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-13Termin

Seite 63 - 7. MHWFLOW

4-14 Intellio C218Turbo /PCI User's ManualRS-485 Programming for Opt8JIf you intend to do RS-485 communication with Opt8J, please follow the RS-

Seite 64

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-15Soluti

Seite 65

4-16 Intellio C218Turbo /PCI User's Manual

Seite 66 - RS-485 Programming for Opt8J

Intellio C218Turbo /PCI User's Manual 5-155555555 5 Connection Option (Opt8x) and Cable WiringIn serial data communications, the term DTE is fo

Seite 67

Intellio C218Turbo /PCI User's Manual 1-111111111 1 IntroductionIntroductionIntroductionIntroductionOverviewIntellio - The Intelligent Multipor

Seite 68

5-2 Intellio C218Turbo /PCI User's ManualThe followings are pin assignments for various connection options:Opt8A/S(DCE, DB25 Female)2RxD3TxD4CTS

Seite 69 - Intellio C218Turbo/PCI

Connection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x

Seite 70

5-4 Intellio C218Turbo /PCI User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt8DOpt8D DTE DeviceDB9 Male DB25 MaleRxD 2 2

Seite 71 - Opt8B/C DTE Device

Connection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x

Seite 72 - Opt8A/S DCE Device

5-6 Intellio C218Turbo /PCI User's ManualType 3: To connect Intellio C218Turbo/PCI to a DTE with 3-pin wiring.If the “Hardware flow control” fea

Seite 73 - Opt8D DCE Device

Connection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x

Seite 74

5-8 Intellio C218Turbo /PCI User's ManualRS-422 Cable Wiring for Opt8J/F/ZRS-422 connection boxes designed for Intellio C218Turbo/PCI are:Opt8J:

Seite 75

Connection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x

Seite 76

5-10 Intellio C218Turbo /PCI User's ManualRS-485 Cable Wiring for Opt8JOne RS-485 connection box designed for Intellio C218Turbo/PCI is:Opt8J: C

Seite 77

Connection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x) and Cable WiringConnection Option (Opt8x

Seite 78 - RS-485 Cable Wiring for Opt8J

1-2 Intellio C218Turbo /PCI User's ManualASIC Design, Compact SizeThe Intellio C218Turbo/PCI is also equipped with MOXA customer-designedASIC c

Seite 79 - RS-422/485 Impedance Matching

5-12 Intellio C218Turbo /PCI User's Manual

Seite 80

Intellio C218Turbo /PCI User's Manual 6-166666666 6 TroubleshootingTroubleshootingTroubleshootingTroubleshootingCommon C218Turbo/PCI problems a

Seite 81 - Troubleshooting

6-2 Intellio C218Turbo /PCI User's ManualSoftware Causes and Solutions:a. Intellio C218Turbo Series will check line status (CTS) before it sends

Seite 82

TroubleshootingTroubleshootingTroubleshootingTroubleshootingIntellio C218Turbo /PCI User's Manual 6-3Windows NTThis section is specific for trou

Seite 83 - Windows NT

6-4 Intellio C218Turbo /PCI User's ManualWindows 95/98This section is specific for troubleshooting under Windows 95/98. For generalproblems and

Seite 84

TroubleshootingTroubleshootingTroubleshootingTroubleshootingIntellio C218Turbo /PCI User's Manual 6-5UNIXThis section is specific for troublesho

Seite 85

6-6 Intellio C218Turbo /PCI User's Manual5. The newly rebuilt kernel could not boot.The C218Turbo/PCI driver might not be built into the new ker

Seite 86

Intellio C218Turbo /PCI User's Manual A-1AAAAAAAA A Technical ReferenceTechnical ReferenceTechnical ReferenceTechnical ReferenceSpecifications

Seite 87 - Technical Reference

A-2 Intellio C218Turbo /PCI User's ManualC218Turbo/PCIWindows NT ✓Windows 95/98 ✓SCO UNIX/OpenServer ✓UNIX SVR4.2 ✓XENIX ✓Linux2.0.x/2.2.x ✓✓

Seite 88 - Dual-Ported RAM

Technical ReferenceTechnical ReferenceTechnical ReferenceTechnical ReferenceIntellio C218Turbo /PCI User's Manual A-3much faster than normal I/O

Seite 89 - DB62 Connector Pinouts

IntroductionIntellio C218Turbo /PCI User's Manual 1-3 Office Automation Telecommunication PC-based (vending) Machine or Kiosk SystemPoint-

Seite 90 - Problem Report Form

Problem Report FormIntellio C218Turbo/PCI Customer name: Company: Tel: Fax: Email: Date:1. Moxa Product: C218Turbo/PCI Serial Number: ______________

Seite 91 - Return Procedure

Return ProcedureFor product repair, exchange or refund, you must: Provide evidence of original purchase  Fill out the Problem Report Form (PRF) as

Kommentare zu diesen Handbüchern

Keine Kommentare