Moxa EtherDevice™ Switch
EDS-600 Series Users Manual
www.moxa.com/product
Second Edition, October 2009
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Seitenansicht 0
1 2 3 4 5 6 ... 144 145

Inhaltsverzeichnis

Seite 1 - EDS-600 Series User’s Manual

Moxa EtherDevice™ Switch EDS-600 Series User’s Manual www.moxa.com/product Second Edition, October 2009 © 2009 Moxa Inc. All rights res

Seite 2

EDS-600 Series User’s Manual Getting Started 2-46. The Console login screen will appear. Press Enter to open the Account pop-up selector and then se

Seite 3 - Table of Contents

EDS-600 Series User’s Manual Featured Functions 3-86Ping The Ping function uses the ping command to give users a simple but powerful tool for troub

Seite 4

EDS-600 Series User’s Manual Featured Functions 3-87LLDP Web Interface From the switch’s web interface, users have the option of either enabling or

Seite 5 - Introduction

EDS-600 Series User’s Manual Featured Functions 3-88Using Monitor You can monitor statistics in real time from the EDS-600’s web console and serial

Seite 6 - Features

EDS-600 Series User’s Manual Featured Functions 3-89Monitor by Port Access the Monitor by Port function by selecting ALL 10/100M or 1G Ports or Port

Seite 7 - Getting Started

EDS-600 Series User’s Manual Featured Functions 3-90The table will display the following information: MAC This field shows the MAC address Type Th

Seite 8

EDS-600 Series User’s Manual Featured Functions 3-91 NOTE The following events will be recorded into the EDS-600’s Event Log table: 1. Cold start 2

Seite 9

EDS-600 Series User’s Manual Featured Functions 3-92Syslog Server 3 Setting Description Factory DefaultIP Address Enter the IP address of 3rd Sys

Seite 10

EDS-600 Series User’s Manual Featured Functions 3-933. Select Yes to enter the EDS-600’s web browser interface and access the web browser interface

Seite 11

44 Chapter 4 EDS Configurator GUI EDS Configurator is a comprehensive Windows-based GUI that is used to configure and maintain multiple EDS-600 sw

Seite 12

EDS-600 Series User’s Manual EDS Configurator GUI 4-2Starting EDS Configurator To start EDS Configurator, locate and then run the executable file ed

Seite 13

EDS-600 Series User’s Manual Getting Started 2-58. After entering the Main Menu, use the following keys to move the cursor, and to select options.

Seite 14

EDS-600 Series User’s Manual EDS Configurator GUI 4-3Broadcast Search Use the Broadcast Search utility to search the LAN for all EDS-600 switches th

Seite 15 - Featured Functions

EDS-600 Series User’s Manual EDS Configurator GUI 4-4Search by IP address This utility is used to search for EDS-600 switches one at a time. Note th

Seite 16 - Configuring Basic Settings

EDS-600 Series User’s Manual EDS Configurator GUI 4-5Upgrade Firmware Keep your EDS-600 up to date with the latest firmware from Moxa. Perform the f

Seite 17 - Password

EDS-600 Series User’s Manual EDS Configurator GUI 4-6Modify IP Address You may use the Modify IP Address function to reconfigure EDS-600’s network s

Seite 18 - Accessible IP

EDS-600 Series User’s Manual EDS Configurator GUI 4-7Export Configuration The Export Configuration utility is used to save the entire configuration

Seite 19

EDS-600 Series User’s Manual EDS Configurator GUI 4-83. You may use a standard text editor, such as Notepad under Windows, to view and modify the n

Seite 20

EDS-600 Series User’s Manual EDS Configurator GUI 4-9Import Configuration The Import Configuration function is used to import an entire configuratio

Seite 21 - Network

EDS-600 Series User’s Manual EDS Configurator GUI 4-103. The Setup Configuration window will be displayed, with a special note attached at the bott

Seite 22

EDS-600 Series User’s Manual EDS Configurator GUI 4-11Unlock Server The Unlock Server function is used to open a password protected switch so that t

Seite 23 - Daylight Saving Time

EDS-600 Series User’s Manual EDS Configurator GUI 4-123. The status of the switch will now read Unlocked.

Seite 24 - IEEE 1588 PTP

EDS-600 Series User’s Manual Getting Started 2-63. The Console login screen will appear. Press Enter to open the Account pop-up selector and then se

Seite 25

AA Appendix A MIB Groups The EDS-600 comes with built-in SNMP (Simple Network Management Protocol) agent software that supports cold/warm start tr

Seite 26 - PTP Setting

EDS-600 Series User’s Manual MIB Groups A-2MIB II.10 – Transmission Group dot3 dot3StatsTable MIB II.11 – SNMP Group SnmpBasicGroup

Seite 27 - Turbo Ring DIP Switch

EDS-600 Series User’s Manual MIB Groups A-3The EDS-600 also provides a private MIB file, located on the EDS-600 Series utility CD-ROM. Public Traps

Seite 28

BB Appendix B Modbus/TCP Map EDS-608 Modbus Information v1.0 Read Only Registers (Support Function Code 4) 1 Word = 2Bytes Address Data Type

Seite 29

EDS-600 Series User’s Manual Modbus/TCP Map B-20x0055 3 word Ethernet MAC Address Ex: MAC = 00-01-02-03-04-05 Word 0 Hi byte = 0x00 Word 0 Lo

Seite 30

EDS-600 Series User’s Manual Modbus/TCP Map B-30x1400~0x1413(Port 1) 0x1414~0x1427(Port 2) 20 word Port 1~8 Description Port Description = "1

Seite 31

EDS-600 Series User’s Manual Modbus/TCP Map B-40x3301 1 word TR 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link Down

Seite 32 - Factory Default

EDS-600 Series User’s Manual Modbus/TCP Map B-50x3502 1 word TR2 Coupling Port Backup status (Only using in Dual Homing) 0x0000:Port Disabled 0x

Seite 33 - Using Port Trunking

EDS-600 Series User’s Manual Modbus/TCP Map B-60x3683 1 word TR2 Ring 2 2nd Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link

Seite 34 - Configuring Port Trunking

EDS-600 Series User’s Manual Modbus/TCP Map B-7EDS-611 Modbus Information v1.0 Read Only Registers (Support Function Code 4) 1 Word = 2Bytes Add

Seite 35

EDS-600 Series User’s Manual Getting Started 2-7NOTE If the EDS-600 is configured for other VLAN settings, you must make sure your PC host is on the

Seite 36 - Configuring SNMP

EDS-600 Series User’s Manual Modbus/TCP Map B-80x005A 1 word Fault LED Status 0x0000:No 0x0001:Yes 0x0080 1 word DI1 0x0000:Off 0x0001:On 0x0082

Seite 37 - SNMP Read/Write Settings

EDS-600 Series User’s Manual Modbus/TCP Map B-90x2200~0x2215 2 word port 1~11 Tx Error Packets Ex: port 1 Tx Error Packets = 0x44332211 Word 0 =

Seite 38 - Trap Settings

EDS-600 Series User’s Manual Modbus/TCP Map B-100x3304 1 word TR Coupling Port status 0x0000:Port Disabled 0x0001:Not Coupling Port 0x0002:Lin

Seite 39 - Private MIB information

EDS-600 Series User’s Manual Modbus/TCP Map B-110x3602 1 word TR2 Ring 1 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link

Seite 40 - Recovery Time < 50 ms

EDS-600 Series User’s Manual Modbus/TCP Map B-120x3702 1 word Turbo Chain 2nd Port Status 0x0000:Link Down 0x0001:Blocking 0x0002:Blocked 0x0003:

Seite 41 - The Turbo Ring Concept

EDS-600 Series User’s Manual Modbus/TCP Map B-130x0055 3 word Ethernet MAC Address Ex: MAC = 00-01-02-03-04-05 Word 0 Hi byte = 0x00 Word 0 Lo

Seite 42

EDS-600 Series User’s Manual Modbus/TCP Map B-140x1400~0x1413(Port 1) 0x1414~0x1427(Port 2) 20 word Port 1~16 Description Port Description = "

Seite 43 - Segment N+1

EDS-600 Series User’s Manual Modbus/TCP Map B-150x3301 1 word TR 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link Down

Seite 44 - Ring Coupling Configuration

EDS-600 Series User’s Manual Modbus/TCP Map B-160x3502 1 word TR2 Coupling Port Backup status (Only using in Dual Homing) 0x0000:Port Disabled 0

Seite 45

EDS-600 Series User’s Manual Modbus/TCP Map B-170x3683 1 word TR2 Ring 2 2nd Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link

Seite 46

EDS-600 Series User’s Manual Getting Started 2-8You may need to wait a few moments for the web page to be downloaded to your computer. Use the menu t

Seite 47 - Configuring “Turbo Ring”

EDS-600 Series User’s Manual Modbus/TCP Map B-18EDS-619 Modbus Information v1.0 Read Only Registers (Support Function Code 4) 1 Word = 2Bytes Ad

Seite 48

EDS-600 Series User’s Manual Modbus/TCP Map B-190x005A 1 word Fault LED Status 0x0000:No 0x0001:Yes 0x0080 1 word DI1 0x0000:Off 0x0001:On 0x008

Seite 49 - Configuring “Turbo Ring V2”

EDS-600 Series User’s Manual Modbus/TCP Map B-200x2200~0x2225 2 word port 1~19 Tx Error Packets Ex: port 1 Tx Error Packets = 0x44332211 Word 0 =

Seite 50

EDS-600 Series User’s Manual Modbus/TCP Map B-210x3304 1 word TR Coupling Port status 0x0000:Port Disabled 0x0001:Not Coupling Port 0x0002:Lin

Seite 51

EDS-600 Series User’s Manual Modbus/TCP Map B-220x3602 1 word TR2 Ring 1 1st Port status 0x0000:Port Disabled 0x0001:Not Redundant 0x0002:Link

Seite 52

EDS-600 Series User’s Manual Modbus/TCP Map B-230x3702 1 word Turbo Chain 2nd Port Status 0x0000:Link Down 0x0001:Blocking 0x0002:Blocked 0x0003:

Seite 53 - The Turbo Chain Concept

33 Chapter 3 Featured Functions In this chapter, we explain how to access the EDS-600’s configuration options, perform monitoring, and use adminis

Seite 54 - Member Switch Configuration

EDS-600 Series User’s Manual Featured Functions 3-2Configuring Basic Settings The Basic Settings group includes the most commonly used settings requ

Seite 55 - Tail Switch Configuration

EDS-600 Series User’s Manual Featured Functions 3-3Web Auto-logout(s) Setting Description Factory Default 60 to 86400 (seconds) Disable or extend

Seite 56

EDS-600 Series User’s Manual Featured Functions 3-4Account Setting Description Factory Default admin “admin” privilege allows the user to modify

Seite 57 - The STP/RSTP Concept

EDS-600 Series User’s Manual Featured Functions 3-5The following table shows additional configuration examples: Allowable Hosts Input format Any ho

Seite 58

Moxa EtherDevice™ Switch EDS-600 Series User’s Manual The software described in this manual is furnished under a license agreement and may be used on

Seite 59 - How STP Works

EDS-600 Series User’s Manual Featured Functions 3-6Speed Setting Description Factory Default Auto Allows the port to use the IEEE 802.3u protocol t

Seite 60 - STP Example

EDS-600 Series User’s Manual Featured Functions 3-7Network The Network configuration allows users to configure both IPv4 and IPv6 parameters for man

Seite 61

EDS-600 Series User’s Manual Featured Functions 3-8Global Unicast Address Setting Description Factory DefaultNone Displays the IPv6 Global Unicas

Seite 62 - Configuring STP/RSTP

EDS-600 Series User’s Manual Featured Functions 3-9NOTE The EDS-600 does not have a real time clock. The user must update the Current Time and Curre

Seite 63

EDS-600 Series User’s Manual Featured Functions 3-10NOTE Changing the time zone will automatically correct the current time. You should configure th

Seite 64 - Using Traffic Prioritization

EDS-600 Series User’s Manual Featured Functions 3-11Can Ethernet switches be designed to avoid the effects of these fluctuations? A switch may be d

Seite 65

EDS-600 Series User’s Manual Featured Functions 3-12PTP Setting Operation IEEE 1588/PTP Setting Description Factory DefaultOperation Disable or e

Seite 66

EDS-600 Series User’s Manual Featured Functions 3-13Turbo Ring DIP Switch The Turbo Ring DIP Switch page allows users to disable the four DIP switch

Seite 67 - QoS Classification

EDS-600 Series User’s Manual Featured Functions 3-14Set DIP switch as Turbo Ring / Set DIP switch as Turbo Ring V2 Setting Description Factory Def

Seite 68 - CoS Mapping

EDS-600 Series User’s Manual Featured Functions 3-15 “Turbo Ring V2” DIP Switch Settings DIP 1 DIP 2 DIP 3 DIP 4 ON: Enables the default “Ring

Seite 69 - TOS/DiffServ Mapping

Table of Contents Chapter 1 Introduction ...1-1 Overview

Seite 70 - Using Virtual LAN

EDS-600 Series User’s Manual Featured Functions 3-16System File Update—By Remote TFTP The EDS-600 supports saving your configuration file to a remot

Seite 71

EDS-600 Series User’s Manual Featured Functions 3-17System File Update—By Local Import/Export Configuration File To export the configuration file o

Seite 72 - Configuring Virtual LAN

EDS-600 Series User’s Manual Featured Functions 3-18Auto load system configurations when system boots up Setting Description Factory DefaultEnable

Seite 73

EDS-600 Series User’s Manual Featured Functions 3-19NOTE After activating the Factory Default function, you will need to use the default network set

Seite 74 - VLAN Table

EDS-600 Series User’s Manual Featured Functions 3-20When you activate Port Trunking settings, some advanced functions that you set up with the origi

Seite 75 - Using Multicast Filtering

EDS-600 Series User’s Manual Featured Functions 3-21Trunk Type Setting Description Factory DefaultStatic Designated Moxa proprietary trunking pro

Seite 76 - Multicast Filtering

EDS-600 Series User’s Manual Featured Functions 3-22Configuring SNMP The EDS-600 supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community stri

Seite 77 - IGMP Multicast Filtering

EDS-600 Series User’s Manual Featured Functions 3-23SNMP Read/Write Settings SNMP Versions Setting Description Factory Default V1, V2c, V3, or V1,

Seite 78 - Configuring IGMP Snooping

EDS-600 Series User’s Manual Featured Functions 3-24User Auth. Type (for SNMP V1, V2c, V3 and V3 only) Setting Description Factory Default No-Auth

Seite 79

EDS-600 Series User’s Manual Featured Functions 3-251st Trap Server IP/Name Setting Description Factory Default IP or Name Enter the IP address or

Seite 80 - Add Static Multicast MAC

Search by IP address... 4-4 Upgrade Firmwar

Seite 81 - GMRP Table

EDS-600 Series User’s Manual Featured Functions 3-26Using Communication Redundancy Setting up Communication Redundancy on your network helps protect

Seite 82 - Using Port Access Control

EDS-600 Series User’s Manual Featured Functions 3-27 NOTE Port trunking and Turbo Ring can be enabled simultaneously to form a backbone. Doing so wi

Seite 83 - The IEEE 802.1X Concept

EDS-600 Series User’s Manual Featured Functions 3-28The user does not need to configure any of the switches as the master to use Turbo Ring or Turbo

Seite 84 - Configuring Static Port Lock

EDS-600 Series User’s Manual Featured Functions 3-29 When the number of EDS units in the Turbo Ring is odd. MasterSegment N+1 If there are 2N+1 EDS

Seite 85 - Configuring IEEE 802.1X

EDS-600 Series User’s Manual Featured Functions 3-30Ring Coupling Configuration For some systems, it may not be convenient to connect all devices in

Seite 86 - 802.1X Re-Authentication

EDS-600 Series User’s Manual Featured Functions 3-31The coupler switch (i.e., Switch A) will monitor switch B through the coupling control port to d

Seite 87 - Port Access Control Table

EDS-600 Series User’s Manual Featured Functions 3-32Dual-Ring Configuration (applies only to “Turbo Ring V2”) The “dual-ring” option provides anothe

Seite 88 - Using Auto Warning

EDS-600 Series User’s Manual Featured Functions 3-33Configuring “Turbo Ring” and “Turbo Ring V2” Use the Communication Redundancy page to configure

Seite 89

EDS-600 Series User’s Manual Featured Functions 3-34Explanation of “Settings” Items Redundancy Protocol Setting Description Factory Default Turbo

Seite 90 - Email Setup

EDS-600 Series User’s Manual Featured Functions 3-35Coupling Control Port Setting Description Factory Default Coupling Control Port Select any por

Seite 91 - Configuring Relay Warning

11 Chapter 1 Introduction Welcome to the Moxa EDS-600 Series of compact modular Ethernet switches designed for connecting Ethernet-enabled devices

Seite 92 - Event Setup

EDS-600 Series User’s Manual Featured Functions 3-36Explanation of “Current Status” Items Now Active Shows which communication protocol is in use: T

Seite 93 - Warning List

EDS-600 Series User’s Manual Featured Functions 3-37Enable Ring 1 Setting Description Factory Default Enabled Enable the Ring 1 settings Disabled

Seite 94 - Using Set Device IP

EDS-600 Series User’s Manual Featured Functions 3-38Coupling Mode Setting Description Factory Default Dual Homing Select this item to change to th

Seite 95 - Configuring Set Device IP

EDS-600 Series User’s Manual Featured Functions 3-39The Turbo Chain Concept Moxa’s Turbo Chain is an advanced software-technology that gives network

Seite 96 - DHCP Option 82

EDS-600 Series User’s Manual Featured Functions 3-40Configuring “Turbo Chain” Head Switch Configuration Member Switch Configuration

Seite 97 - Server IP Address

EDS-600 Series User’s Manual Featured Functions 3-41Tail Switch Configuration Explanation of “Current Status” Items Now Active Shows which communic

Seite 98 - DHCP Fnction Table

EDS-600 Series User’s Manual Featured Functions 3-42Head Role Setting Description Factory Default Head Port Select any port of the EDS to be the h

Seite 99 - Using Diagnosis

EDS-600 Series User’s Manual Featured Functions 3-43The STP/RSTP Concept Spanning Tree Protocol (STP) was designed to help reduce link failures in a

Seite 100 - LLDP Function Overview

EDS-600 Series User’s Manual Featured Functions 3-44If STP is enabled, it will detect duplicate paths and prevent, or block, one of them from forwar

Seite 101 - LLDT Table

EDS-600 Series User’s Manual Featured Functions 3-45How STP Works When enabled, STP determines the most appropriate path for traffic through a netwo

Seite 102 - Using Monitor

EDS-600 Series User’s Manual Introduction 1-2Overview The versatile modular design of the compact EDS-600series Ethernet switches allow users to com

Seite 103 - Using the MAC Address Table

EDS-600 Series User’s Manual Featured Functions 3-46STP Reconfiguration Once the network topology has stabilized, each bridge listens for Hello BPDU

Seite 104 - Using Event Log

EDS-600 Series User’s Manual Featured Functions 3-47y Bridge A has been selected as the Root Bridge, since it was determined to have the lowest Bri

Seite 105 - Using Syslog

EDS-600 Series User’s Manual Featured Functions 3-48Configuring STP/RSTP The following figures indicate which Spanning Tree Protocol parameters can

Seite 106 - Using HTTPS/SSL

EDS-600 Series User’s Manual Featured Functions 3-49Forwarding Delay Setting Description Factory DefaultNumerical value input by user The amount o

Seite 107

EDS-600 Series User’s Manual Featured Functions 3-50Port Status Indicates the current Spanning Tree status of this port. “Forwarding” for normal tra

Seite 108 - EDS Configurator GUI

EDS-600 Series User’s Manual Featured Functions 3-51The Traffic Prioritization Concept What is Traffic Prioritization? Traffic prioritization allows

Seite 109 - Starting EDS Configurator

EDS-600 Series User’s Manual Featured Functions 3-52Even though the IEEE 802.1D standard is the most widely used prioritization scheme in the LAN en

Seite 110 - Broadcast Search

EDS-600 Series User’s Manual Featured Functions 3-53EDS-600 supports two different queuing mechanisms: y Weight Fair: This method services all the

Seite 111 - Search by IP address

EDS-600 Series User’s Manual Featured Functions 3-54Port Highest Priority Setting Description Factory DefaultEnable/Disable Set the Port Priority

Seite 112 - Upgrade Firmware

EDS-600 Series User’s Manual Featured Functions 3-55 Setting Description Factory Low/Normal/ Medium/High Set the mapping table of different CoS va

Seite 113 - Modify IP Address

22 Chapter 2 Getting Started This chapter explains how to access the EDS-600 for the first time. There are three ways to access the switch: serial

Seite 114 - Export Configuration

EDS-600 Series User’s Manual Featured Functions 3-56Using Virtual LAN Setting up Virtual LANs (VLANs) on your EDS-600 increases the efficiency of yo

Seite 115

EDS-600 Series User’s Manual Featured Functions 3-57Benefits of VLANs The main benefit of VLANs is that they provide a network segmentation system

Seite 116 - Import Configuration

EDS-600 Series User’s Manual Featured Functions 3-58The IEEE Std 802.1Q-1998 defines how VLANs operate within an open packet-switched network. An 80

Seite 117

EDS-600 Series User’s Manual Featured Functions 3-59Management VLAN ID Setting Description Factory DefaultVLAN ID ranges from 1 to 4094 Set the ma

Seite 118 - Unlock Server

EDS-600 Series User’s Manual Featured Functions 3-60To configure the EDS-600’s Port-based VLAN, use the VLAN Setting page to configure the ports. V

Seite 119

EDS-600 Series User’s Manual Featured Functions 3-61In 802.1Q VLAN table, you can review the VLAN groups that were created, Joined Access Ports, and

Seite 120 - MIB Groups

EDS-600 Series User’s Manual Featured Functions 3-62Multicast Filtering Multicast filtering ensures that only end-stations that have joined certai

Seite 121

EDS-600 Series User’s Manual Featured Functions 3-63Multicast Filtering and Moxa EtherDevice Switch The EDS-600 has three ways to achieve multicast

Seite 122

EDS-600 Series User’s Manual Featured Functions 3-64GMRP (GARP Multicast Registration Protocol) The EDS-600 supports IEEE 802.1D-1998 GMRP (GARP Mul

Seite 123 - Modbus/TCP Map

EDS-600 Series User’s Manual Featured Functions 3-65IGMP Snooping Enhanced Mode Setting Description Factory DefaultEnable IGMP Multicast packets

Seite 124

EDS-600 Series User’s Manual Getting Started 2-2RS-232 Console Configuration (115200, None, 8, 1, VT100) NOTE Connection Caution! 1. You cannot conn

Seite 125

EDS-600 Series User’s Manual Featured Functions 3-66IGMP Table The EDS-600 displays the current active IGMP groups that were detected. The informat

Seite 126

EDS-600 Series User’s Manual Featured Functions 3-67Configuring GMRP GMRP is a MAC-based multicast management protocol, whereas IGMP is IP-based. GM

Seite 127

EDS-600 Series User’s Manual Featured Functions 3-68Using Bandwidth Management In general, one host should not be allowed to occupy unlimited bandwi

Seite 128

EDS-600 Series User’s Manual Featured Functions 3-69The IEEE 802.1X Concept Three components are used to create an authentication mechanism based on

Seite 129

EDS-600 Series User’s Manual Featured Functions 3-701. When the supplicant receives an “EAP Request/Identity” frame, it sends an “EAP Response/Iden

Seite 130

EDS-600 Series User’s Manual Featured Functions 3-71Configuring IEEE 802.1X Database Option Setting Description Factory DefaultLocal (Max. 32 use

Seite 131

EDS-600 Series User’s Manual Featured Functions 3-72Re-Auth Setting Description Factory DefaultEnable/Disable Select to require re-authentication

Seite 132

EDS-600 Series User’s Manual Featured Functions 3-73Local User Database Setup When setting the Local User Database as the authentication database, s

Seite 133

EDS-600 Series User’s Manual Featured Functions 3-74Using Auto Warning Since industrial Ethernet devices are often located at the endpoints of a sys

Seite 134

EDS-600 Series User’s Manual Featured Functions 3-75Event Types can be divided into two basic groups: System Events and Port Events. System Events a

Seite 135

EDS-600 Series User’s Manual Getting Started 2-33. The Communication Parameter page of the Property window opens. Select the appropriate COM port fo

Seite 136

EDS-600 Series User’s Manual Featured Functions 3-76 NOTE Warning e-mail messages will have the sender field formatted as follows: Moxa EDS-608, 000

Seite 137

EDS-600 Series User’s Manual Featured Functions 3-77Password Setting Setting Description Factory DefaultDisable/Enable to change Password To reset

Seite 138

EDS-600 Series User’s Manual Featured Functions 3-78Event Setup Event Types can be divided into two basic groups: System Events and Port Events. Sy

Seite 139

EDS-600 Series User’s Manual Featured Functions 3-79 Port Events Warning e-mail is sent when… Link-ON The port is connected to another device. Li

Seite 140

EDS-600 Series User’s Manual Featured Functions 3-80Using Line-Swap-Fast-Recovery The Line-Swap Fast Recovery function, which is enabled by default,

Seite 141

EDS-600 Series User’s Manual Featured Functions 3-81Perform the following steps to use the Set device IP function: STEP 1—set up the connected devic

Seite 142

EDS-600 Series User’s Manual Featured Functions 3-82The DHCP Relay Agent makes it possible for DHCP broadcast messages to be sent over routers. The

Seite 143

EDS-600 Series User’s Manual Featured Functions 3-83 Server IP Address 1st Server Setting Description Factory DefaultIP address for the 1st DHCP s

Seite 144

EDS-600 Series User’s Manual Featured Functions 3-84DHCP Option 82 Enable Option82 Setting Description Factory DefaultEnable or Disable Enable or

Seite 145

EDS-600 Series User’s Manual Featured Functions 3-85Using Diagnosis The EDS-600 provides two important tools for administrators to diagnose network