Moxa Technologies CP-132U Series Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Netzwerk-Switches Moxa Technologies CP-132U Series herunter. Moxa Technologies CP-132U Series User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 19
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Moxa TCC-100 Series
User’s Guide
Tenth Edition, September 2011
www.moxa.com/product
© 2011 Moxa Inc. All rights reserved.
P/N: 1802001000318
Seitenansicht 0
1 2 3 4 5 6 ... 18 19

Inhaltsverzeichnis

Seite 1 - User’s Guide

Moxa TCC-100 Series User’s Guide Tenth Edition, September 2011 www.moxa.com/product © 2011 Moxa Inc. All rights reserved. P/N: 1802001000318

Seite 2

6 WARNING 1. The DC source should come from an external adaptor or 12 to 48 VDC source (not from DC mains) by using a transfer device. 2. This uni

Seite 3

7 LED Indicators The TCC-100’s top panel contains three LED indicators, as described in the following table: LED Name LED Function PWR Red indicates

Seite 4 - Table of Contents

2 2. Installation This chapter includes information about how to install TCC-100 products, and shows function and block diagrams. The following topi

Seite 5 - Introduction

9 Hardware Installation Installing the TCC-100 involves six straightforward steps: • STEP 1: Set the DIP switches • STEP 2: Attach the power supply

Seite 6 - Overview

10 4-wire RS-485 SW1 SW2 SW3 OFF ON OFF 2-wire RS-485 (terminator active) SW1 SW2 SW3 OFF OFF ON 2-wire RS-485 SW1 SW2 SW3 OFF OFF OFF The DIP-2 s

Seite 7

11 STEP 2: Attach the power supply The TCC-100 is powered by an external 12 to 48 VDC power supply. To connect the power supply, run two wires from

Seite 8 - Product Specifications

12 RS-422 When using the RS-422 wiring option, first follow the 4-wire RS-485 wiring instructions given above. Optional RTS/CTS Handshaking Signals

Seite 9

13 characters were transmitted between the TCC-100’s RS-232 port and RS-422/485 terminal block connector. STEP 6: Placement Options In addition to pl

Seite 10 - Schematic

14 Function Diagram Isolation Block Diagram Typical Applications RS-485 Application A typical RS-485 application for the TCC-100 series is shown in

Seite 11 - LED Indicators

15 RS-422 Application A typical RS-422 application for the TCC-100 Series is shown in the following figure. In this scenario, two TCC-100 units are

Seite 12 - Installation

Moxa TCC-100 Series User’s Guide The software described in this manual is furnished under a license agreement and may be used only in accordance wit

Seite 13 - Hardware Installation

Technical Support Contact Information www.moxa.com/support Moxa Americas Toll-free: 1-888-669-2872 Tel: +1-714-528

Seite 14

Table of Contents 1. Introduction ... 1 Overview...

Seite 15

1 1. Introduction TCC-100 series consists of RS-232 to RS-422/485 media converters. The “I” versions, the TCC-100I/TCC-100I-T come with 2 KV isolati

Seite 16

2 Overview Many important devices used in today’s industrial environment are still designed for use with an RS-232 interface. The reason is due in pa

Seite 17 - Termination Resistor Diagram

3 RTS/CTS RS-422 Handshaking Signals The TCC-100 series supports RS-422 handshaking signals. The RTS and CTS signals help solve the RS-422 signal han

Seite 18 - Isolation Block Diagram

4 Product Features • RS-232 to RS-422 conversion with RTC/CTS support • RS-232 to 2/4-wire RS-485 conversion • Detachable wall and DIN-Rail mounti

Seite 19

5 Isolation 2 KV (TCC-100I/TCC-100I-T) for both power and signal Environmental Limits Operating Temperature TCC-100/TCC-100I: -20 to 60°C (-4 to 1

Kommentare zu diesen Handbüchern

Keine Kommentare