Moxa TCC-100 Series User’s Guide Tenth Edition, September 2011 www.moxa.com/product © 2011 Moxa Inc. All rights reserved. P/N: 1802001000318
6 WARNING 1. The DC source should come from an external adaptor or 12 to 48 VDC source (not from DC mains) by using a transfer device. 2. This uni
7 LED Indicators The TCC-100’s top panel contains three LED indicators, as described in the following table: LED Name LED Function PWR Red indicates
2 2. Installation This chapter includes information about how to install TCC-100 products, and shows function and block diagrams. The following topi
9 Hardware Installation Installing the TCC-100 involves six straightforward steps: • STEP 1: Set the DIP switches • STEP 2: Attach the power supply
10 4-wire RS-485 SW1 SW2 SW3 OFF ON OFF 2-wire RS-485 (terminator active) SW1 SW2 SW3 OFF OFF ON 2-wire RS-485 SW1 SW2 SW3 OFF OFF OFF The DIP-2 s
11 STEP 2: Attach the power supply The TCC-100 is powered by an external 12 to 48 VDC power supply. To connect the power supply, run two wires from
12 RS-422 When using the RS-422 wiring option, first follow the 4-wire RS-485 wiring instructions given above. Optional RTS/CTS Handshaking Signals
13 characters were transmitted between the TCC-100’s RS-232 port and RS-422/485 terminal block connector. STEP 6: Placement Options In addition to pl
14 Function Diagram Isolation Block Diagram Typical Applications RS-485 Application A typical RS-485 application for the TCC-100 series is shown in
15 RS-422 Application A typical RS-422 application for the TCC-100 Series is shown in the following figure. In this scenario, two TCC-100 units are
Moxa TCC-100 Series User’s Guide The software described in this manual is furnished under a license agreement and may be used only in accordance wit
Technical Support Contact Information www.moxa.com/support Moxa Americas Toll-free: 1-888-669-2872 Tel: +1-714-528
Table of Contents 1. Introduction ... 1 Overview...
1 1. Introduction TCC-100 series consists of RS-232 to RS-422/485 media converters. The “I” versions, the TCC-100I/TCC-100I-T come with 2 KV isolati
2 Overview Many important devices used in today’s industrial environment are still designed for use with an RS-232 interface. The reason is due in pa
3 RTS/CTS RS-422 Handshaking Signals The TCC-100 series supports RS-422 handshaking signals. The RTS and CTS signals help solve the RS-422 signal han
4 Product Features • RS-232 to RS-422 conversion with RTC/CTS support • RS-232 to 2/4-wire RS-485 conversion • Detachable wall and DIN-Rail mounti
5 Isolation 2 KV (TCC-100I/TCC-100I-T) for both power and signal Environmental Limits Operating Temperature TCC-100/TCC-100I: -20 to 60°C (-4 to 1