5210/5230 User’s Manual First Edition, May 2003 Moxa Technologies Co., Ltd. Tel: +866-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com service
Panel Layout NPort 5210 NPort 5230 Connecting the Hardware This section describes how to connect NPort 5210/5230 to serial devices for first
Getting Started If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment. Temperature Caut
Connecting to the Network Connect one end of the Ethernet cable to NPort 5210/5230’s 10/100M Ethernet port and the other end of the cable to the Ethe
33 Chapter 3 Initial IP Address Configuration When setting up your NPort 5210/5230 for the first time, the first thing you should do is configuring
NPort Administration Suite NPort Administration Suite consists of some useful utility programs that are used to configure and manage your NPorts. See
Initial IP Address Configuration Telnet Console Depending on how your computer and network are configured, you may find it convenient to use network a
6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter. 7. Press any key to continue… 8. Type
Initial IP Address Configuration 9. Type s and then press Enter to Save/Restart the system. 10. Type y and then press Enter to save the new IP addres
6. Press the “ ` ” continuously and then power on the NPort. 7. NPort will receive the “ ` ” string continuously and then auto switch from data
44 Chapter 4 Choosing the Proper Operation Mode In this section, we describe the various NPort operation modes. The options include an operation m
5210 / 5230 User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the t
Overview NPort Device Servers network-enable traditional RS-232/422/485 devices, in which a Device Server is a tiny computer equipped with a CPU, rea
Choosing the Proper Operation Mode TCP Client Mode In TCP Client mode, NPort can actively establish a TCP connection to a pre-defined host computer wh
Real COM Mode NPort comes equipped with COM drivers that work with Windows 95/98/ME/NT/2000/XP systems, and also TTY drivers for Linux systems. The d
55 Chapter 5 Web Console Configuration The Web Console is the most user-friendly way to configure NPort 5210/5230. This chapter will introduce the
Opening Your Browser 1. Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Interne
Web Console Configuration 4. The NPort 5210/5230 homepage will open. On this page, you can see a brief description of the Web Console’s nine function
Basic Settings Server name Setting Factory Default Necessity 1 to 29 characters NP[model name]_[Serial No.] Optional This option is useful for s
Web Console Configuration Local time Setting Factory Default Necessity User adjustable time. GMT (Greenwich Mean Time) Optional Click on the Modi
Network Settings You must assign a valid IP address to NPort 5210/5230 before it will work in your network environment. Your network system administ
Web Console Configuration Netmask Setting Factory Default Necessity Ex. 255.255.255.0 255.255.0.0 Required A subnet mask represents all the networ
Table of Contents Chapter 1 Introduction... 1-1 Overv
SNMP Settings Community Name Setting Factory Default Necessity 1 to 39 characters (E.g., Support, 886-89191230 #300) public Optional A community na
Web Console Configuration Auto report period Setting Factory Default Necessity Time interval (in seconds) 10 Optional Serial Settings Click on Se
Serial Parameters Check the serial communication parameters in your Serial Device’s user’s manual. You should set up NPort’s serial parameters with
Web Console Configuration Operating Settings Press Operating Settings to display the operating settings for all of NPort’s serial ports. Real COM Mod
Max Connection Setting Factory Default Necessity 1, 2, 3, 4 1 Required Max Connection is usually used when the user needs to receive data from d
Web Console Configuration Force Transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0: Disable the force transmit timeout. 1 to
Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 ms: TCP connection is not closed due to an idle serial line. 0-65
Web Console Configuration Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data
TCP Client Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an
Web Console Configuration At least, the Inactivity time should be set larger than that of Force Transmit timeout. To prevent the unintended loss of d
Chapter 6 Configuring Windows Administrator ... 6-1 Overview ...
Destination IP address 1 Setting Factory Default Necessity IP address or Domain Address (E.g., 192.168.1.1) None Required Allows NPort to connect act
Web Console Configuration UDP Mode Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Once the NPort receives both delimiters
Force Transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0: Disable the force transmit timeout. 1 to 65535: Forces the NPort’
Web Console Configuration Accessible IP Settings NPort has an IP address based filtering method to control access to the NPort. Accessible IP Settin
Auto Warning Settings Event Type Cold start This refers to starting the system from power off (contrast this with warm start). When performing a col
Web Console Configuration DSR changed The DSR (Data Set Ready) signal has changed, also indicating that the data communication equipment’s power is o
Auto warning: E-mail and SNMP Trap Mail Server Mail Server Setting Factory Default Necessity IP or Domain Name None Optional User Name Setting
Web Console Configuration Change Password Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase
Load Factory Default This function will reset all of NPort’s settings to the factory default values. Be aware that previous settings will be lost.
66 Chapter 6 Configuring Windows Administrator The following topics are covered in this chapter: Overview Installing Windows Administrator C
11 Chapter 1 Introduction Welcome to MOXA NPort 5200 Series of advanced serial device servers that make it easy to network enable your serial devic
Overview We understand the importance of software as the foundation of your application, and with this in mind, we designed NPort Administrator to le
Configuring Windows Administrator 4. Click on Next to install the program using the default program name, or select a different name. 5. Click on Ins
8. Click on Finish to complete the installation of NPort Administration Suite. Configuration The Administrator-Configuration window is divided into
Configuring Windows Administrator Broadcast Search The Broadcast Search function is used to locate all NPorts that are connected to the same LAN as yo
Unlock Password Protection If the NPort is password protected, then you will not be able to use the right click or double click method to open the c
Configuring Windows Administrator Blank The NPort is not password protected, and “Broadcast Search” was used to locate it. Fixed The NPort is not pass
Upgrade Firmware Input the password to Unlock the NPort, and then right click on a specific NPort and select the Upgrade Firmware function to start u
Configuring Windows Administrator Export/Import Right click on a specific NPort and select the Export function to start Exporting the configuration f
Monitor There are two methods available to start the Monitor function. 1. First use Broadcast Search under the Configuration Function group, and then
Configuring Windows Administrator Select Monitor Items. Select a Refresh Rate (the default is 3 seconds). Select Display warning message or Play the
Overview NPort 5200 Series serial device servers are designed to make your industrial serial devices Internet ready instantly. The compact size of NP
When one of the NPorts loses connection with the Monitor program, a warning alert will display automatically. The warning music will be played at the
Configuring Windows Administrator Port Monitor The process is the same as in the previous “Monitor” section. The only difference is that you can selec
COM Mapping Windows Administration Suite comes with the Windows 95/98/ME/NT/2000/XP Real COM drivers. After you install Windows Administration Suite,
Configuring Windows Administrator Select COM Setting to modify COM No., default setting, etc. Select the COM No. Those “In use,” “Assigned” COM ports
After setting the COM Mapping, remember to select the Apply Change to save the information in the host system registry. The host computer will not ha
Configuring Windows Administrator Off-line COM Mapping Add a target by inputting the IP address and selecting the Model Name without physically connec
IP Location When NPort 5000 series products are used in a dynamic IP environment, users must spend more time with IP management tasks. NPort 5000 ser
77 Chapter 7 IP Serial LIB The following topics are covered in this chapter: Overview IP Serial LIB Function Groups Example Program
Overview What is IP Serial Library? IP Serial Library is a Windows library with frequently used serial command sets and subroutines. IP Serial Librar
IP Serial LIB IP Serial LIB Function Groups Server Control Port Control Input/Output Data Port Status Inquiry Miscellaneous nsio_init nsio_end nsio_
Introduction Product Specifications LAN Ethernet 10/100 Mbps, RJ45 Protection Built-in 1.5 KV magnetic isolation NPort 5210 Serial Interface Interf
AA Appendix A Pinouts and Cable Wiring In this appendix, we cover the following topics. Port Pinout Diagrams Ethernet Port Pinouts Serial P
Port Pinout Diagrams Ethernet Port Pinouts Serial Port Pinouts 8-pin RJ45 RS-232 Port Pinouts for NPort 5210 Terminal Block RS-232 & RS-422/4
Pinouts and Cable Wiring Cable Wiring Diagrams Ethernet Cables Serial Cables 8-pin RJ45 to DB25 Female for NPort 5210 (Cable Name: CBL-RJ45F2
8-pin RJ45 to DB25 Male for NPort 5210 (Cable Name: CBL-RJ45M25-150) 8-pin RJ45 to DB9 Female for NPort 5210 (Cable Name: CBL-RJ45F9-150) 8-pin
BB Appendix B Well Known Port Numbers This appendix is for your reference about the Well Known port numbers that may cause network problem if you
49 (Login Host Protocol) (Login) 53 Domain Name Server (domain) 79 Finger protocol (Finger) TCP Socket Application Service 80 World Wibe Web HTTP
CC Appendix C SNMP Agent with MIB II & RS-232 like group NPort 5200 has a built-in SNMP (Simple Network Management Protocol) agent software. I
System MIB Interfaces MIB IP MIB ICMP MIB SysServices ifInUnknownProtos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs i
SNMP Agent with MIB II & RS-232 like group Address Translation MIB TCP MIB SNMP MIB AtNetAddress tcpRetransSegs snmpInTotalSetVars tcpConnSta
DD Appendix D Service Information This appendix shows you how to contact Moxa for information about this and other products, and how to report pro
Power Requirements Power Input 12 to 30 VDC Power Consumption NPort 5210: 305 mA at 12V (max.) NPort 5230: 315 mA at 12V (max.) Mechanical
MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa I
Service Information Problem Report Form MOXA NPort 5200 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product: NPort 5210
NPort 5210/5230 User’s Manual D-4Product Return Procedure For product repair, exchange, or refund, the customer must: Provide evidence of original
22 Chapter 2 Getting Started This chapter includes information about installing NPort 5210/5230. The following topics are covered: Panel Layout
Kommentare zu diesen Handbüchern